| 1. “Yoked” prism __________________________________. |
|
A.
|
deviates light equally in the same direction |
|
B.
|
deviates light equally in opposite directions |
|
C.
|
causes diplopia |
|
D.
|
both B & C |
|
|
| 2. Prism thinning is usually ____________________________. |
|
A.
|
prescribed by the refractionist as part of the patient's Rx |
|
B.
|
used to challenge an extra-ocular muscles |
|
C.
|
calculated at the laboratory |
|
D.
|
applied to glass lenses only |
|
|
| 3. The primary purpose of prism thinning is ______________________. |
|
A.
|
to reduce differences in thickness between the left and right lens |
|
B.
|
to reduce differences in thickness between the top and bottom of the lens |
|
C.
|
to reduce the overall thickness and weight of the lens |
|
D.
|
both B & C |
|
|
| 4. The curvature of a progressive power lens _________________ towards the bottom of the lens. |
|
A.
|
increases |
|
B.
|
decreases |
|
C.
|
remains stable |
|
D.
|
may either decrease or increase |
|
|
| 5. Which of the following statements regarding this prescription are true? OU -1.00 sph ADD +2.00 |
|
A.
|
the combined near power is +2.00 diopters |
|
B.
|
the combined near power is +1.00 diopters |
|
C.
|
the combined near power is plano |
|
D.
|
the combined near power is -1.00 diopters |
|
|
| 6. What factors are generally taken into account when determining if prism thinning will be applied? |
|
A.
|
the location of the Primary Reference Point (PRP) |
|
B.
|
the combined near power of the lens |
|
C.
|
the relative thickness of the top and bottom of the lens |
|
D.
|
all of the above |
|
|
| 7. The “datum line” is a _______________________________________. |
|
A.
|
horizontal line passing through the geometric center of the lens |
|
B.
|
vertical line passing through the geometric center of the lens |
|
C.
|
equivalent to the ED measurement of the frame |
|
D.
|
both B & C |
|
|
| 8. Prism thinning may not be applied by some LMS (Lab Management Systems) if the PRP ____________________________. |
|
A.
|
is located above the datum line |
|
B.
|
is located on the datum line |
|
C.
|
is located below the datum line |
|
D.
|
both A & B |
|
|
| 9. Most patients ___________________________ changes in prism thinning. |
|
A.
|
are extremely sensitive to |
|
B.
|
will notice some effect with |
|
C.
|
will adapt over time to |
|
D.
|
will not notice |
|
|
| 10. A patient who is sensitive to the addition of prism thinning may report ___________________. |
|
A.
|
feeling like he “is walking uphill all the time” |
|
B.
|
feeling like he “is walking downhill all the time” |
|
C.
|
blurred distance vision |
|
D.
|
diplopia (double-vision) |
|
|
| 11. A patient who is used to prism thinning may notice its absence in future eyewear by reporting ____________________________. |
|
A.
|
a feeling like he “is walking uphill all the time” |
|
B.
|
a feeling like he “is walking downhill all the time” |
|
C.
|
a feeling the reading area is lower in the frame |
|
D.
|
diplopia (double-vision) |
|
|
| 12. Generally speaking, the amount of prism thinning usually applied is _____________________. |
|
A.
|
equal to 1/3 the ADD power |
|
B.
|
equal to ½ the ADD power |
|
C.
|
equal to 2/3 the ADD power |
|
D.
|
equal to the ADD power |
|
|
| 13. Generally speaking, the maximum amount of prism thinning applied should be ____________. |
|
A.
|
1.00 diopter |
|
B.
|
1.50 diopter |
|
C.
|
2.00 diopter |
|
D.
|
2.50 diopter |
|
|
| 14. Prism thinning should be measured at the _________________. |
|
A.
|
fitting cross |
|
B.
|
near verification circle |
|
C.
|
distance verification circle |
|
D.
|
PRP (Primary Reference Point) |
|
|
| 15. Unless Rx prism has been ordered, the amount of prism at the PRP of should be ___________. |
|
A.
|
the same in both lenses |
|
B.
|
4.00 diopters base up in both lenses |
|
C.
|
4.00 diopters base down in both lenses |
|
D.
|
in equal amounts but opposite directions in each lens |
|
|
| 16. When looking through a prism, the eye will rotate towards the _____________. |
|
A.
|
base of the prism |
|
B.
|
apex of the prism |
|
C.
|
mid-point of the prism |
|
D.
|
optical center of the prism |
|
|
| 17. Prism thinning is generally considered to be a ________________ element of the eyewear. |
|
A.
|
refractive |
|
B.
|
cosmetic |
|
C.
|
prescribed |
|
D.
|
undesirable |
|
|
| 18. Which of the following Rxs is most likely to have prism thinning applied? |
|
A.
|
OU -3.50 sph ADD +1.00 |
|
B.
|
OU -3.50 sph ADD +3.00 |
|
C.
|
OU -1.50 sph ADD +1.00 |
|
D.
|
OU -1.50 sph ADD +3.00 |
|
|
| 19. If a patient appears to be sensitive to a change in prism thinning, the eyewear should be _______________________. |
|
A.
|
reordered with a lower fitting height |
|
B.
|
reordered with a higher fitting height |
|
C.
|
reordered with prism thinning equal to the previous pair |
|
D.
|
reordered with prism thinning greater than the previous pair |
|
|
| 20. The PRP is located ____________________________. |
|
A.
|
mid-way between the engraved circles on the PAL |
|
B.
|
4mm above the engraved circles on the PAL |
|
C.
|
at the fitting cross |
|
D.
|
2.5mm inset from the fitting cross |
|